| Filling principle | Isobaric, CO2 counter-pressure |
| Rated output | 12,000-36,000 BPH at 0.2-2 L |
| Containers | PET bottle, glass bottle, aluminum can |
| CO2 handling | Pre-pressurisation and return pipe, no venting |
| Valves | Mechanical, semi-electric or volumetric |
| Line scope | Water treatment, syrup mixing, carbonation, filler, pack |
Four points decide it: the carbonation level set at the mixer, the product temperature at the filler, the pressure profile during fill, and the time between capping and packing. A line that holds 4.0 volumes at the mixer can deliver 3.4 in the bottle if the filler bowl runs warm or the capping head leaks.
From optimizing the injection process and preserving CO2 levels to extending shelf life and enhancing flavor retention, these dosers are instrumental in delivering products that meet and exceed consumer expectations.
Syrup is proportioned and blended with treated water, then carbonated under pressure and temperature control. The ratio accuracy and the carbonation stability decide the product, and both are upstream of the filler. A filler cannot correct a drifting blend.
Through the precise regulation of CO2 levels, nitrogen dosers play a vital role in extending the shelf life of carbonated soft drinks.
| Valve type | Setting | Best for |
|---|---|---|
| Mechanical | Fixed cam profile | Single product, long runs |
| Semi-electric | Signal-timed open and close | Recipe changes within one product family |
| Volumetric | Chamber dose | Pressure or temperature drift during the shift |
| Isobaric + volumetric | Chamber dose under counter-pressure | High CO2 with tight fill accuracy |
Valve count, utility schedule and footprint sit on the CSD & Sparkling Water by Mechanical Filler page.
Warm product holds less CO2 at the same pressure, so the filler either loses gas or needs a higher pressure that increases foaming. Chilling before carbonation is the standard answer, and the chiller capacity belongs in the utility schedule.
The Isobaric Filling Machine for CSD and Sparkling Water is the reference unit for this configuration.
Overfoaming is gas leaving the product too fast at the end of fill. The pressure release has to be ramped, not dumped, and the fill height has to leave the right headspace. A snift valve that opens too early turns a good fill into a wet bottle.
The same question is worked through from another angle in Carbon Mixer at 15 C: How CO2 Retention Is.
It holds what the mixer sets and the temperature allows. Most CSD runs between 2.5 and 4.0 volumes, with the target set per product. Retention, not the mixer set point, is what the acceptance test should measure in the filled bottle.
Usually product temperature rising in the bowl or a worn valve seal. Both change the pressure balance, so the fill cuts off earlier. Log bowl temperature and fill weight together for one shift before changing any valve.
It is used where the package needs internal pressure support or low oxygen, for example in cans and in some PET formats. It is an option, not a default, and it adds a consumable cost per 1,000 units.
Yes, with a different infeed, spacing and capping set. Glass needs mechanical spacing rather than an air conveyor, and the filler runs at 4,000-20,000 BPH on glass against 12,000-36,000 BPH on PET.
Country: Kazakhstan
Product: PET Bottled Carbonated Soft Drinks
Capacity: 12000BPH (1L)
Solution:Carbonated Drinks Production Line
Country: Syria
Product: Aluminum Canned Carbonated Soft Drinks
Capacity: 24000CPH (250ml)
Solution:Carbonated Drinks Production Line