| Filling system | Load cell net-weight, or piston dosing |
| Capacity range | 12,000-36,000 BPH at 0.2-2 L |
| Viscosity | Up to 10,000 cP |
| Accuracy | Plus or minus 0.5 g per bottle |
| Bottle or can | PET or glass |
| Key control | Weight per bottle, temperature, drip-free cut-off |
Oil clings. A valve that cuts off cleanly on water leaves a thread of oil on the bottle shoulder, and that thread becomes a rejected bottle and a dirty conveyor. The cut-off profile, the nozzle tip and the suck-back setting are the three things to watch at acceptance, not the fill speed.
Above a few thousand cP the product moves by pressure and time rather than by gravity, so the bowl, the feed pipe and the valve bore all grow. Temperature control also becomes part of the filling specification, because a cold oil at 10 C and the same oil at 25 C behave like two different products.
| Dosing method | Accuracy basis | When it fits |
|---|---|---|
| Load cell | Net weight per bottle | Density moves with temperature |
| Piston | Displacement volume | Stable density, high speed, thick product |
| Volumetric valve | Chamber volume | Low-viscosity oil at steady temperature |
| Flow meter | Measured volume | Continuous flow, limited pulp or solids |
For the same duty in another bottle format, the Edible Oil Load Cell is specified separately.
Weigh a fixed sample at the start, middle and end of a shift, on the same scale, and record the temperature at the same time. A filler that holds plus or minus 0.5 g at a steady 25 C may drift at 18 C. Acceptance without a temperature record is an argument waiting to happen.
Throughput and change-part lists are on the Filling Machine for Viscous Product page rather than in this note.
With a warm flush and a full drain, because oil does not rinse like water. The circuit needs a low point for drainage and a filter on the return. A change between two oils is quicker than a change from oil to a water-based product.
The same question is worked through from another angle in Benefits of Using Load Cell Combiblocs for Edible Oil.
Nothing, if the filler tares each bottle before dosing. That tare step is what separates net-weight filling from a flow meter. Without it, a heavy bottle delivers less product and the label claim fails.
Usually air entrained in the product or a fill that starts too fast. Letting the product settle in the bowl and ramping the valve opening removes most of it without changing the pump.
Some packers dose nitrogen into the headspace to slow oxidation, especially for polyunsaturated oils. It is an option, and its value depends on the oil and the target shelf life, not on the filler.
The temperature at which the viscosity gives a clean cut-off and a repeatable weight, held steady through the shift. The exact band belongs to the product specification; the requirement is that it is controlled and recorded.
Product temperature, a worn valve seat, or scale calibration. Log the weight and the temperature together; a drift that follows temperature is a process problem, not a valve problem.
No. Oil is filled at the temperature that gives a clean cut-off and a stable weight. Heating is used to lower viscosity when the product is cold, not to preserve it.
Country: Kazakhstan
Product: PET Bottled Carbonated Soft Drinks
Capacity: 12000BPH (1L)
Solution:Carbonated Drinks Production Line
Country: Maldives
Product: PET Bottled Mineralized Water
Capacity: 24,000BPH (500ml); 2 Lines
Solution:Water Production Line